XL Scan Unsquelch Duration

(Secure Wide, Features)

HGDefinitionMob%26Port.jpg

Selects the amount of time that the radio waits in active scan mode for a SecureNet-encrypted XL (range extended) signal to be detected following a carrier detect. This feature applies for Conventional communications on a radio wide basis. Time is in milliseconds.

HGAccessedOnly.jpg

When the Secure Operation field is set to "Hardware", and

when the radio is model / option capable.

HGSelections.jpg

Minimum

Maximum

Increments

0 (ms)

6375 (ms)

25 (ms)

IconSmallNote.png

ms = milliseconds

GoArrow.jpg